跳至主要内容

Is your home heating ready? ——Wall-hung boiler

Winter is coming, is your fireplace ready to turn on?
Have you done a few tasks before starting up?

Step1 Water, electricity, gas and pipeline inspection

1. Confirm that the pipeline valve is open, and pay attention to whether the pipeline system is dripping or leaking;


※When installing a heating system with a radiator, pay attention to the temperature control valve on the radiator.


※When installing a floor heating system, you need to pay attention to the collector and distributor. First, open the valve of the main water supply pipeline of the water divider. When the temperature of the hot water gradually rises and is injected into the pipeline to circulate, check whether the connection of the water divider is abnormal, and then gradually open the branch valves of the water divider to check the operation status.







2. Confirm that the power is on;

3. Confirm that the gas valve is open, and check the sealing performance of the natural gas pipeline and all joints at the same time, whether there is any natural gas leakage in the home
Happening.


Step2 Water pressure control check

The water pressure of the wall-hung boiler should be controlled between 1.0-2.0bar. If the water pressure is lower than 1.0bar, the water supply valve should be opened to make up water, and the pressure should be adjusted to the normal range before starting.

1. First check whether there is a leak in the heating system and confirm that the system is completely airtight;

2. Find the water make-up valve at the bottom of the boiler and open the make-up valve to make up water;

3. Observe the water pressure gauge on the operation panel. When the pointer of the water pressure gauge is between 1.0-2.0bar, you can turn the water supply valve in the reverse direction and turn on the boiler.

※If the water supply valve is not closed in time, it will cause a flooding accident


Step3 Unblock the "gas block" of the pipeline

After turning on the heating mode, pay attention to whether the heating system is heating normally. If you find that the heating is not hot, don't worry, it may be "air block". After a heating season, the air precipitated by the hot water in the heating pipes gathers in the pipes, which will hinder the normal flow of hot water in the system pipes, causing the heat transfer radiator to fail to work normally.

'※If the floor heating is installed, it must be exhausted on the manifold
※If you install a radiator, you need to vent on the vent valve

Heatcold is a global professional indoor temperature and air solution application expert, always focusing on intelligent control solutions in the field of comfortable home furnishings, and is committed to creating products and services that can bring people joy.

评论